ADIC SNC 5100 Guia do Utilizador Página 46

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 228
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 45
SNC 5100
38 Event Codes and Actions
6-00020-02
33
3
1 1 An interface has detected a bus fault
(event message indicates the specific
interface)
1, 2
34
3
1 1 An interface has detected a device
fault
(event message indicates the specific
interface)
1, 2
35 1 1 A SCSI interface reported an
unexpected disconnect by a device
1
36 1 1 A parity error was detected on a SCSI
bus
1
37 2 0 Fibre Channel Port Database change
detected
0
39 1 1 Directory Server on Fabric has
changed
0
40 1 1 Maximum LUN limit has been
exceeded
10
41 1 0 Fibre Channel transfer failure
(Caution: error recovery may have
succeeded)
0
42 1 1 Maximum device limit has been
exceeded (persistent Address Map
database is full)
10
43 1 1 Fibre Channel interface driver
reported debug file dump (event log
contains further information)
13
58 1 1 Power has returned to Nominal from
Warning or Alarm Stage
0
59 1 1 Power has entered Warning Range
from Nominal Range (Power falling)
or Alarm Range (Power improving)
5
60 1 1 Power has entered Alarm Range 5
Table 7: Event Codes and Actions
Event
Code
Viewing
Level
1
Default
Trap
Threshold
Description
Action
2
Vista de página 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 227 228

Comentários a estes Manuais

Sem comentários