ADIC SNC 5100 Guia do Utilizador Página 44

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 228
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 43
SNC 5100
36 Event Codes and Actions
6-00020-02
N.A. N.A. N.A. Persistent reboots 3
N.A. N.A. N.A. Host application error message or host
log entry indicates SCSI target error
12
N.A. N.A. N.A. Host cannot access attached devices 12
N.A. N.A. N.A. SAN Connection LED off although
cables are attached and host systems
are on and have booted
2
N.A. N.A. N.A. Heartbeat failure 7
N.A. N.A. N.A.
fcShow command returns
Firmware State = Sync
Lost
2, 0
N.A. N.A. N.A. ADIC Management Console failure 7
N.A. N.A. N.A. Service terminal connection failure 8
Generic Event Descriptions
8 2 0 Sense data recorded following a check
condition
Caution: Normally, the host system
will request and process send data and
then perform error recovery
0
9 1 0 LUN reports a unit attention
condition on a non-removable media
device
0
11 1 1 ADIC Management Console reports a
temperature change (event message
indicates the change to High, Very
High, Reduced, to High, or OK
4
13 1 1 SNC 5100 is shutting down as
requested by the ADIC Management
Console
(a Restart was requested)
0
14 0 0 Additional status information used for
diagnostics
0
Table 7: Event Codes and Actions
Event
Code
Viewing
Level
1
Default
Trap
Threshold
Description
Action
2
Vista de página 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 227 228

Comentários a estes Manuais

Sem comentários