Adic Scalar 1000 Manual do Utilizador Página 21

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 20
nineteen
All specifications subject to change without notice. All products and company names should be considered trademarks of their respective companies.
Scalar
®
and ADIC
®
are trademarks of Advanced Digital Information Corporation. DLT™ and DLTtape™ are trademarks of Quantum Corporation. AIT™ is a trademark of Sony Corporation
®
.
3590 & Magstar are trademarks of IBM Corporation
®
. © Copyright 1999 Advanced Digital Information Corporation.
Library Configurations
Scalar 1000
DLT7000 DLT8000
DLT DLT Total Total
Tape Capacity Drives Cartridges Capacity
1
Capacity
1
Base Control Module: 1 to 12 118 to 158 11.1TB 12.6TB
With 1 Expansion Module: 1 to 24 248 to 368 25.8TB 29.4TB
With 2 Expansion Modules: 1 to 36 378 to 578 40.5TB 46.2TB
With 3 Expansion Modules: 1 to 48 508 to 788 55.2TB 63.0TB
Drive and Performance
Drive Type: DLT7000 DLT8000
Data Cartridge Capacity
Native: 35GB 40GB
with 2:1 Compression: 70GB 80GB
Transfer Rate per drive
Native: 300MB/min 360MB/min
with Compression: 600MB/min
File Access Time (Avg): 60 seconds
Data Compression: On-board DCLZ with variable block size
Recording Format: Multiple Track, Linear Serpentine
Data Buffer: 8MB, cache buffer adjusts to host rates
Media: DLTtape™ IV
Tape Length: 1800 feet
Recording Density: 86,000 bits/in 100,000 bits/in
Tracks Per Tape: 208
Error Correction Code: Reed Solomon ECC; 64-bit CRC on each
4KB of data; 16-bit CRC on each record;
Internal parity checking on cache buffer
Operation
Cartridge Change: 6 seconds maximum
Indicators: Password-protected keypad with LCD
menu display
Drive: Write Protected, Tape in Use,
Use Cleaning Tape, and Tape Density LEDs;
Density Select, Tape Unload Controls
Drive Interface: Fast and Wide SCSI-2 Differential
Library Interface: SCSI-2 Differential
SCSI Connections: 68-pin micro-D
Reliability
Hard Error Rate: Less than 1 in 10
17
bits read
Tape Shelf Life: 30 years minimum (at 20°C, 40% RH)
Maintenance: Periodic drive head cleaning with
DLT Cleaning Cartridge
MSBF: Greater than 1,000,000 cartridge changes
MTTR: Less than 30 minutes
Field Replaceable: Drives, Power Supplies, Gripper Assembly,
Barcode Reader, Control Electronics Module,
Hot Swappable Drives
2
Diagnostics: Built-In-Test (BIT), Store/Recall Past Events,
“Fault Isolation” Assistance, Self Initiating
Configuration and Calibration Routines
Physical
Control Module: 29.5"W x 47"D x 72"H
(74.9cm x 119.4cm x 182.9cm)
Weight: 1052 lbs. (477Kg) maximum weight
Expansion Module: 29.5"W x 47"D x 72"H
(74.9cm x 119.4cm x 182.9cm)
Weight: 817 lbs (372Kg)
Environmental
Electrical: 115/230 VAC, 1.6kVa
Altitude: 30,000 feet
Temperature: 16°C to 32°C Operating
Humidity: 15 to 75% Non-Condensing Operating
Compliance and Certification
Year 2000 Compliant
Safety: UL-1950 ITE, CSA950, EN 60950
Emissions: FCC #47 CFR, Part 15, Class A, CSA C108.8M,
EN 55022, Class A
Immunity: IEC (1000-4-2, 3, 4)
International: CE
Software and Platforms
Consult the most recent ADIC Software Compatibility Guide for a
complete list of software and platforms compatible with the Scalar
Series.
1
with 2:1 compression.
2
without affecting library operation. Bus integrity must be sustained.
Scalar 1000 / DLT Specifications
Year 2000
Compliant
Vista de página 20